New Paradigm of Digital Panoramic Imaging
![]() |
New Technologies in the PaX-500 Series 1) X-ray exposure time reduced to 0.9 sec: One Shot CephalometricDSSI (Dual Shot Signal Integration) technology Eliminates motion artifacts in cephalometric image 2) Eliminates blurred image of the incisor ALC (Adaptive Layer Control) technology 3) Achieves high-definition cephalometric image DUET (DUal EnhancemenT) algorithm Quality imaging not only for hard bone, but also for soft tissue 4) Guarantees stable signal transfer CAN (Controller Area Network) system Ensures high system reliability and convenience for maintenance |
|---|---|
![]() |
The Most Advanced Technology
|
![]() |
PaX-500 Versa (Scan Type Cephalometric) DUET - Dual EnhancemenT Algorithm
Dual speed vertical movement Motorized and weight balanced up / down movement guarantees fast and easy height adjustment with no vibration and low noise. |
![]() |
PaX-500 OS Pro (OneShot Cephalometric) Optimized for Orthodontics with Minimum Exposure Time
1) Reduced X-ray DoseIt reduces X-ray dose to 1/2 with regards to the patient in growth period. 2) Double Sensitivity Clear image using Area Sensor with double sensitivity compared to Film. 3) No Image Distortion Uses Big-Size Flat Panel Detector |
Product Function
- 1. Sensor Attachment/Detachment Method
- One digital sensor attached and detached is enabled for panorama or cephalo imaging.
- 2. Scan-Type Cephalometric/One-shot
- Scan Time: 12.9 sec/0.9 sec
- 3. LCD Touch Screen
- By simply touching the 6.4 inch LCD Touch Screen, you can confirm the imaging setting and find the pictures taken.
- 4. LCD Window for Patient Guidance:
- Through the LCD Panel in front of the equipment, it guides patients on the imaging procedure with letters and voice.
- 5. Embedded Camera for Patient Positioning
- It enables checking and correcting the patient's posture through the LCD Panel.
- 6. Up/Down Sliding Frame
- The height of an equipment is adjusted easily according to the patient's height.
- 7. Auto Moving Chinrest
- Auto positioning of the chin rest for the imaging part offers more convenience for patients.
| Focal Spot | 0.5 mm | ||
|---|---|---|---|
| Data Bit | 16 bit | ||
| Scan Time | Panorama | Fast | 9.1 sec |
| Normal | 12.9 sec | ||
| Cephalo | Versa | 12.5 sec | |
| OS Pro | 0.9 sec(standard mood) | ||
| Power | 110/220V, 1.3kw | ||
| Tube Voltage | 40~90 kVp | ||
| Tube Current | 2-10mA | ||
| Data Acquisition speed | 20Mb/s | ||
| Dimension (WxDxH in) | 43.9 x 45.3 x 86.6 | ||
| The specifications are subject to change without prior notice. | |||